<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="pt-BR">
	<id>https://gatewiki.ifi.unicamp.br/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Mseren</id>
	<title>GATE Wiki - Contribuições do usuário [pt-br]</title>
	<link rel="self" type="application/atom+xml" href="https://gatewiki.ifi.unicamp.br/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Mseren"/>
	<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php/Especial:Contribui%C3%A7%C3%B5es/Mseren"/>
	<updated>2026-05-25T12:16:29Z</updated>
	<subtitle>Contribuições do usuário</subtitle>
	<generator>MediaWiki 1.43.8</generator>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Cintiladores&amp;diff=239</id>
		<title>Cintiladores</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Cintiladores&amp;diff=239"/>
		<updated>2025-09-10T12:00:33Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Criação&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
* &#039;&#039;&#039;Cintilador NaI(Tl) - Serial Number 241003-7&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;ID:&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Local de Uso e Armazenamento:&#039;&#039; Laboratório de Ensino em Física Médica (LEP/LF-46) &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Data de Aquisição:&#039;&#039; 19/05/2025 (Entrega FEDEX - Número de rastreamento: 4638 7837 097) &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Modalidade da Aquisição:&#039;&#039; Importação com verba do Edital PRG Alegra II (SEC 16758/2024) &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Fornecedor:&#039;&#039; TelAtomic &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Fotos do produto  no momento da entrega: (cintilador + suporte+blindagem de chumbo+ cabos MHV e BNC)&#039;&#039;&lt;br /&gt;
[[Arquivo:Cintilador e acessorios.jpg|centro|miniaturadaimagem|Cintilador NaI(Tl) - SN 241003-7: Conjunto de cintilador, suporte, blindagens e cabos. ]]&lt;br /&gt;
&#039;&#039;&#039;&#039;&#039;Dados do Equipamento:&#039;&#039;&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Fabricante:&#039;&#039; Rexon Components, Inc. &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Número de Série:&#039;&#039; 241003-7&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Desempenho do equipamento medido pelo fabricante a 600V, com fonte de Cs-137:&#039;&#039; &lt;br /&gt;
[[Arquivo:Cintilador SN241003-7.jpg|centro|miniaturadaimagem|577x577px|Cintilador NaI(Tl) - SN 241003-7: Espectro padrão com fonte de Cs-137, realizado com 600V, 1024 canais por 120.000 segundos. ]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:Cintilador_e_acessorios.jpg&amp;diff=238</id>
		<title>Arquivo:Cintilador e acessorios.jpg</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:Cintilador_e_acessorios.jpg&amp;diff=238"/>
		<updated>2025-09-10T11:56:18Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Conjunto de cintilador, suporte e cabos.&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:Cintilador_SN241003-7.jpg&amp;diff=237</id>
		<title>Arquivo:Cintilador SN241003-7.jpg</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:Cintilador_SN241003-7.jpg&amp;diff=237"/>
		<updated>2025-09-10T11:52:03Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Medida padrão do cintilador NaI(Tl), feita pelo fabricante a 600V, com fonte de Cs-137.&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=202</id>
		<title>Tubo GM - 35mm - G35.06</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=202"/>
		<updated>2024-10-11T14:30:19Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== &#039;&#039;&#039;IDENTIFICAÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Camberra Dover, Inc&lt;br /&gt;
&lt;br /&gt;
Modelo: Mica end window TP2131&lt;br /&gt;
&lt;br /&gt;
Número de série: -&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 35mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: GM35.06 (ou GM03)&lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Data de Aquisição: 10/09/2009 (Processo de Compra: 1-P-27301/2009)&lt;br /&gt;
&lt;br /&gt;
Data de Recebimento: 19/11/2009&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|700V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|975 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|66 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== &#039;&#039;&#039;Plateau&#039;&#039;&#039; ===&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 700V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 5V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 60 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM35-06.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27236).|borda]]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial&lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|640V&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|700V&lt;br /&gt;
|980V a 1020V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|09/10/2024&lt;br /&gt;
|700V&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|975V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; ==&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1lhoYZVk0BUU2J-UXcfrYYj0LiNPE4NyI/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 01/02/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|640V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|83.2 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time&lt;br /&gt;
|2.6x10&amp;lt;sup&amp;gt;-6&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;ROTEIROS EXPERIMENTAIS (Restrito aos Técnicos e Docentes do Laboratório)&#039;&#039;&#039; ==&lt;br /&gt;
Roteiro sugerido pelo fornecedor: [https://drive.google.com/file/d/1qutpM7VMQCFUVr57CWPkalFblTPKK22z/view?usp=drive_link Instructor’s Version]&lt;br /&gt;
&lt;br /&gt;
Roteiro sugerido pelo fornecedor: [https://drive.google.com/file/d/12L1QZ1yV5sIvVxtObbkR45it20YGYsZQ/view?usp=drive_link Student Version]&lt;br /&gt;
&lt;br /&gt;
Outros:&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1qHGxXGTlABBeaFnzhi4GkPnRB35pKgrb/view?usp=drive_link Attenuation Range]&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1DLWGCjai0d21zkTraMnYLlkoRWMouKAr/view?usp=drive_link Characteristics of a Geiger-Müller (end-window) Counter Tube]&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1E03xddn_EdFGVCcYoe-5mFro3JxyeULY/view?usp=drive_link Determining the energy loss of α radiation in air]&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1YELsSRuPQKqm8h2Mi8z_DM0ttCl6qe0S/view?usp=drive_link Poisson distribution]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;LINKS ÚTEIS&#039;&#039;&#039; ==&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1bqTssqc-sm-70cQaKnRpZih_FazK-FJf/view?usp=drive_link Gas-Filled Radiation Detectors]&lt;br /&gt;
&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1Y-dFthEaC-4N5E-VL2Hx1m92BOvNsD1g/view?usp=drive_link Geiger Mueller Tube Brochure]&lt;br /&gt;
&lt;br /&gt;
Camberra: [https://drive.google.com/file/d/1o7cZNLyHQS2DjWKgvAhuL11Iy4Kg0diX/view?usp=drive_link GM End Window Detectors]&lt;br /&gt;
&lt;br /&gt;
Google Patentes: [https://patents.google.com/patent/US4359661A/en US4359661A - Geiger-Mueller tube with tungsten liner]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=201</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=201"/>
		<updated>2024-10-11T14:28:30Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Inserção Roteiros Experimentais&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== &#039;&#039;&#039;IDENTIFICAÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Data de Aquisição: 10/09/2009 (Processo de Compra: 1-P-27301/2009) &lt;br /&gt;
&lt;br /&gt;
Data de Recebimento: 19/11/2009&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|45 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== &#039;&#039;&#039;Plateau&#039;&#039;&#039; ===&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).|borda]]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; ==&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;ROTEIROS EXPERIMENTAIS (Restrito aos Técnicos e Docentes do Laboratório)&#039;&#039;&#039; ==&lt;br /&gt;
Roteiro sugerido pelo fornecedor: [https://drive.google.com/file/d/1qutpM7VMQCFUVr57CWPkalFblTPKK22z/view?usp=drive_link Instructor’s Version]&lt;br /&gt;
&lt;br /&gt;
Roteiro sugerido pelo fornecedor: [https://drive.google.com/file/d/12L1QZ1yV5sIvVxtObbkR45it20YGYsZQ/view?usp=drive_link Student Version]&lt;br /&gt;
&lt;br /&gt;
Outros: &lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1qHGxXGTlABBeaFnzhi4GkPnRB35pKgrb/view?usp=drive_link Attenuation Range] &lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1DLWGCjai0d21zkTraMnYLlkoRWMouKAr/view?usp=drive_link Characteristics of a Geiger-Müller (end-window) Counter Tube]&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1E03xddn_EdFGVCcYoe-5mFro3JxyeULY/view?usp=drive_link Determining the energy loss of α radiation in air]&lt;br /&gt;
&lt;br /&gt;
[https://drive.google.com/file/d/1YELsSRuPQKqm8h2Mi8z_DM0ttCl6qe0S/view?usp=drive_link Poisson distribution]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;LINKS ÚTEIS&#039;&#039;&#039; ==&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1bqTssqc-sm-70cQaKnRpZih_FazK-FJf/view?usp=drive_link Gas-Filled Radiation Detectors]&lt;br /&gt;
&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1Y-dFthEaC-4N5E-VL2Hx1m92BOvNsD1g/view?usp=drive_link Geiger Mueller Tube Brochure]&lt;br /&gt;
&lt;br /&gt;
Camberra: [https://drive.google.com/file/d/1o7cZNLyHQS2DjWKgvAhuL11Iy4Kg0diX/view?usp=drive_link GM End Window Detectors]&lt;br /&gt;
&lt;br /&gt;
Google Patentes: [https://patents.google.com/patent/US4359661A/en US4359661A - Geiger-Mueller tube with tungsten liner]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=200</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=200"/>
		<updated>2024-10-11T14:16:44Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Inserção de Links Úteis&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== &#039;&#039;&#039;IDENTIFICAÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Data de Aquisição: 10/09/2009 (Processo de Compra: 1-P-27301/2009) &lt;br /&gt;
&lt;br /&gt;
Data de Recebimento: 19/11/2009&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|45 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== &#039;&#039;&#039;Plateau&#039;&#039;&#039; ===&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).|borda]]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; ==&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
== &#039;&#039;&#039;LINKS ÚTEIS&#039;&#039;&#039; ==&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1bqTssqc-sm-70cQaKnRpZih_FazK-FJf/view?usp=drive_link Gas-Filled Radiation Detectors]&lt;br /&gt;
&lt;br /&gt;
Saint-Gobain: [https://drive.google.com/file/d/1Y-dFthEaC-4N5E-VL2Hx1m92BOvNsD1g/view?usp=drive_link Geiger Mueller Tube Brochure]&lt;br /&gt;
&lt;br /&gt;
Camberra: [https://drive.google.com/file/d/1o7cZNLyHQS2DjWKgvAhuL11Iy4Kg0diX/view?usp=drive_link GM End Window Detectors]&lt;br /&gt;
&lt;br /&gt;
Google Patentes: [https://patents.google.com/patent/US4359661A/en US4359661A - Geiger-Mueller tube with tungsten liner]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=199</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=199"/>
		<updated>2024-10-11T14:04:17Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Editoração - Inclusão de data do Recebimento&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;== &#039;&#039;&#039;IDENTIFICAÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Data de Aquisição: 10/09/2009 (Processo de Compra: 1-P-27301/2009) &lt;br /&gt;
&lt;br /&gt;
Data de Recebimento: 19/11/2009&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|45 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=== &#039;&#039;&#039;Plateau&#039;&#039;&#039; ===&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).|borda]]&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039; ==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; ==&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=192</id>
		<title>Tubo GM - 35mm - G35.06</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=192"/>
		<updated>2024-10-09T17:57:51Z</updated>

		<summary type="html">&lt;p&gt;Mseren: BG - 09/10/2024&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Camberra Dover, Inc&lt;br /&gt;
&lt;br /&gt;
Modelo: Mica end window TP2131&lt;br /&gt;
&lt;br /&gt;
Número de série: -&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 35mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: GM35.06 (ou GM03)&lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|700V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|975 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|66 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 700V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 5V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 60 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM35-06.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27236).|borda]]&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial&lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|640V&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|700V&lt;br /&gt;
|980V a 1020V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|09/10/2024&lt;br /&gt;
|700V&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|975V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1lhoYZVk0BUU2J-UXcfrYYj0LiNPE4NyI/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 01/02/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|640V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|83.2 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time&lt;br /&gt;
|2.6x10&amp;lt;sup&amp;gt;-6&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=191</id>
		<title>Tubo GM - 35mm - G35.06</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=191"/>
		<updated>2024-10-09T17:53:33Z</updated>

		<summary type="html">&lt;p&gt;Mseren: INSERÇÃO LINK&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Camberra Dover, Inc&lt;br /&gt;
&lt;br /&gt;
Modelo: Mica end window TP2131&lt;br /&gt;
&lt;br /&gt;
Número de série: -&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 35mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: GM35.06 (ou GM03)&lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|700V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|975 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 700V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 5V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 60 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM35-06.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27236).|borda]]&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial&lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|640V&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|700V&lt;br /&gt;
|980V a 1020V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|09/10/2024&lt;br /&gt;
|700V&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|975V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1lhoYZVk0BUU2J-UXcfrYYj0LiNPE4NyI/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 01/02/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|640V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|83.2 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time&lt;br /&gt;
|2.6x10&amp;lt;sup&amp;gt;-6&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=190</id>
		<title>Tubo GM - 35mm - G35.06</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=190"/>
		<updated>2024-10-09T17:51:05Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Camberra Dover, Inc&lt;br /&gt;
&lt;br /&gt;
Modelo: Mica end window TP2131&lt;br /&gt;
&lt;br /&gt;
Número de série: -&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 35mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: GM35.06 (ou GM03)&lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|700V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|975 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 700V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 5V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 60 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM35-06.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27236).|borda]]&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial&lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|640V&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|700V&lt;br /&gt;
|980V a 1020V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|09/10/2024&lt;br /&gt;
|700V&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|975V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Relatório Completo (aqui)&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 01/02/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|640V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|800V a 940V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|870V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|83.2 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time&lt;br /&gt;
|2.6x10&amp;lt;sup&amp;gt;-6&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=189</id>
		<title>Tubo GM - 35mm - G35.06</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_35mm_-_G35.06&amp;diff=189"/>
		<updated>2024-10-09T17:34:33Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Criou página com &amp;#039;* &amp;#039;&amp;#039;&amp;#039;IDENTIFICAÇÃO:&amp;#039;&amp;#039;&amp;#039;  Tipo do dispositivo: Tubo Geiger-Mueller, End Window  Marca: Camberra Dover, Inc  Modelo: Mica end window TP2131  Número de série: -  Diâmetro da Janela: 35mm  Identificação Local: GM35.06 (ou GM03)  Registro no sistema de patrimônio interno: Não há &amp;#039;&amp;#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&amp;#039;&amp;#039;  * &amp;#039;&amp;#039;&amp;#039;STATUS NA ÚLTIM...&amp;#039;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Camberra Dover, Inc&lt;br /&gt;
&lt;br /&gt;
Modelo: Mica end window TP2131&lt;br /&gt;
&lt;br /&gt;
Número de série: -&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 35mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: GM35.06 (ou GM03)&lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27233 a 08/27236 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|700V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|950V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|975 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 700V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 5V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 60 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM35-06.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27236).|borda]]&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial&lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial&lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time&lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:GM35-06.jpg&amp;diff=188</id>
		<title>Arquivo:GM35-06.jpg</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:GM35-06.jpg&amp;diff=188"/>
		<updated>2024-10-09T17:34:07Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Plateau do Tubo GM35.06 - Adquirido em 09/10/2024&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=187</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=187"/>
		<updated>2024-10-09T17:17:04Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Editoração da Página e inclusão do BG&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|45 CPM&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|alt=Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).|borda]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=186</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=186"/>
		<updated>2024-10-09T17:16:01Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|borda|esquerda|Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=185</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=185"/>
		<updated>2024-10-09T17:15:20Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há &#039;&#039;(Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009).&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|borda|esquerda|Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;MEDIDAS ANTERIORES&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
!Data&lt;br /&gt;
!Tensão Inicial &lt;br /&gt;
!Geiger-Plateau&lt;br /&gt;
!Tensão de Operação&lt;br /&gt;
|-&lt;br /&gt;
|31/01/2013&lt;br /&gt;
|840V&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|830V&lt;br /&gt;
|950V a 1110V&lt;br /&gt;
|1030V&lt;br /&gt;
|-&lt;br /&gt;
|13/08/2022&lt;br /&gt;
|850V&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|980V&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;DADOS DE REFERÊNCIA (2013)&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Relatório Completo [https://drive.google.com/file/d/1igaNIxIPlKWupqJdPlYWXUPoQG3AFyB4/view?usp=drive_link (aqui)]&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! colspan=&amp;quot;2&amp;quot; |Data: 31/01/2013&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|840V&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|920V a 1080V&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|1000V&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|33.6 CPM&lt;br /&gt;
|-&lt;br /&gt;
|Resolving Time &lt;br /&gt;
|7.76x10&amp;lt;sup&amp;gt;-8&amp;lt;/sup&amp;gt; CPM&amp;lt;sup&amp;gt;-1&amp;lt;/sup&amp;gt;&lt;br /&gt;
|}&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=184</id>
		<title>Tubo GM - 25mm - n115</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Tubo_GM_-_25mm_-_n115&amp;diff=184"/>
		<updated>2024-10-09T16:56:35Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Criou página com &amp;#039;* &amp;#039;&amp;#039;&amp;#039;IDENTIFICAÇÃO:&amp;#039;&amp;#039;&amp;#039;   Tipo do dispositivo: Tubo Geiger-Mueller, End Window  Marca: Saint-Gobain Crystals  Modelo: N204/BNC  Número de série: 0844  Diâmetro da Janela: 25mm  Identificação Local: #115   Registro no sistema de patrimônio interno: Não há (Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009)  * &amp;#039;&amp;#039;&amp;#039;STATUS NA ÚLTIMA AFERIÇÃO&amp;#039;&amp;#039;&amp;#039;  {| class=&amp;quot;wikitable...&amp;#039;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* &#039;&#039;&#039;IDENTIFICAÇÃO:&#039;&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Tipo do dispositivo: Tubo Geiger-Mueller, End Window&lt;br /&gt;
&lt;br /&gt;
Marca: Saint-Gobain Crystals&lt;br /&gt;
&lt;br /&gt;
Modelo: N204/BNC&lt;br /&gt;
&lt;br /&gt;
Número de série: 0844&lt;br /&gt;
&lt;br /&gt;
Diâmetro da Janela: 25mm&lt;br /&gt;
&lt;br /&gt;
Identificação Local: #115 &lt;br /&gt;
&lt;br /&gt;
Registro no sistema de patrimônio interno: Não há (Sonda de pequeno porte não passível de chapeamento. A sonda está agregada ao equipamento P.I. 08/27232 de acordo com o processo nº 01-P-27301/2009)&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;STATUS NA ÚLTIMA AFERIÇÃO&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+&lt;br /&gt;
! colspan=&amp;quot;3&amp;quot; |Data: 09/10/2024&lt;br /&gt;
|-&lt;br /&gt;
!Item Verificado&lt;br /&gt;
!Status&lt;br /&gt;
!Observações&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual da janela&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual parede &lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Inspeção visual conectores&lt;br /&gt;
|OK&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão Inicial &lt;br /&gt;
|850V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Geiger Plateau&lt;br /&gt;
|960V a 1000V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|Tensão de Operação Indicada&lt;br /&gt;
|980 V&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|BG&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|}&lt;br /&gt;
&#039;&#039;&#039;Plateau&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Condições de aquisição do gráfico:&lt;br /&gt;
&lt;br /&gt;
Tensão Inicial: 600V&lt;br /&gt;
&lt;br /&gt;
Tensão Final: 1000V&lt;br /&gt;
&lt;br /&gt;
Step: 10V&lt;br /&gt;
&lt;br /&gt;
Tempo por Step: 30 seg&lt;br /&gt;
[[Arquivo:GM-114-2024.jpg|borda|esquerda|Plateau do Tubo GM. Dados adquiridos em 09/10/2024 no sistema STX/Spectrum Techniques - Usando ST360 (P.I. 08/27234).]]&lt;br /&gt;
&lt;br /&gt;
*&lt;br /&gt;
&lt;br /&gt;
*&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:GM-114-2024.jpg&amp;diff=183</id>
		<title>Arquivo:GM-114-2024.jpg</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:GM-114-2024.jpg&amp;diff=183"/>
		<updated>2024-10-09T16:54:50Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Plateau do Tubo GM #115 - Adquirido em 09/10/2024&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=172</id>
		<title>GATE</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=172"/>
		<updated>2024-10-02T12:12:04Z</updated>

		<summary type="html">&lt;p&gt;Mseren: atualização&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;O Grupo de Apoio Técnico Especializado (GATE) foi instituído em março de 2019 no Instituto de Física Gleb Wataghin (IFGW).&lt;br /&gt;
&lt;br /&gt;
O objetivo do GATE é fornecer suporte abrangente para o ensino, pesquisa e extensão, contando com uma equipe altamente qualificada e multidisciplinar.&lt;br /&gt;
&lt;br /&gt;
Atualmente, o GATE está estruturado em três setores: Apoio Acadêmico (APA), Apoio Técnico e Suporte (ATS) e Operação de Equipamentos Multiusuários (OEM).&lt;br /&gt;
&lt;br /&gt;
O setor [[APA|GATE/APA]] é responsável por oferecer apoio técnico para a operação e manutenção dos equipamentos científicos utilizados em pesquisas e no ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
O setor [[ATS|GATE/ATS]] presta serviços de suporte técnico aos laboratórios de pesquisa, incluindo elaboração de desenhos técnicos, confecção de peças, fornecimento de fluidos criogênicos, manutenção de bombas de vácuo, soldas especiais e confecção e reparo de utensílios de quartzo.&lt;br /&gt;
&lt;br /&gt;
O setor [[OEM|GATE/OEM]], por sua vez, é responsável pela operação e gestão do parque de equipamentos multiusuários do IFGW, que inclui LAMULT, Equipamentos do Acervo Controlado (EAC) e Equipamentos Multiusuários (EMU).  &lt;br /&gt;
&lt;br /&gt;
O setor [[EIT|GATE/EIT]] trata do apoio com projetos de eletrônica e instrumentação.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
A seguir podem ser encontradas informações importantes sobre procedimentos internos:&lt;br /&gt;
&lt;br /&gt;
[[Informações Internas]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos_Laborat%C3%B3rios_de_Ensino&amp;diff=171</id>
		<title>Equipamentos Laboratórios de Ensino</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos_Laborat%C3%B3rios_de_Ensino&amp;diff=171"/>
		<updated>2024-10-02T11:57:29Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* Laboratório de Eletrônica (LF-44): &lt;br /&gt;
* Laboratório de Ensino de Física Médica (LF-46)&lt;br /&gt;
* Laboratório de Física Moderna (LF-47)&lt;br /&gt;
* Laboratório de Óptica (LF-42)&lt;br /&gt;
* Laboratório de Ensino de Raios X (LF-41)&lt;br /&gt;
* Laboratório de Vácuo e Criogenia (LF-43)&lt;br /&gt;
* Laboratório de Ensino Básico (LEB)&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=170</id>
		<title>GATE</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=170"/>
		<updated>2024-10-02T11:55:27Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;O Grupo de Apoio Técnico Especializado (GATE) foi instituído em março de 2019 no Instituto de Física Gleb Wataghin (IFGW).&lt;br /&gt;
&lt;br /&gt;
O objetivo do GATE é fornecer suporte abrangente para o ensino, pesquisa e extensão, contando com uma equipe altamente qualificada e multidisciplinar.&lt;br /&gt;
&lt;br /&gt;
Atualmente, o GATE está estruturado em três setores: Apoio Acadêmico (APA), Apoio Técnico e Suporte (ATS) e Operação de Equipamentos Multiusuários (OEM).&lt;br /&gt;
&lt;br /&gt;
O setor [[APA|GATE/APA]] é responsável por oferecer apoio técnico para a operação e manutenção dos equipamentos científicos utilizados em pesquisas e no ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
O setor [[ATS|GATE/ATS]] presta serviços de suporte técnico aos laboratórios de pesquisa, incluindo elaboração de desenhos técnicos, confecção de peças, fornecimento de fluidos criogênicos, manutenção de bombas de vácuo, soldas especiais e confecção e reparo de utensílios de quartzo.&lt;br /&gt;
&lt;br /&gt;
O setor [[OEM|GATE/OEM]], por sua vez, é responsável pela operação e gestão do parque de equipamentos multiusuários do IFGW, que inclui LAMULT, Equipamentos do Acervo Controlado (EAC) e Equipamentos Multiusuários (EMU).  &lt;br /&gt;
&lt;br /&gt;
O setor [[EIT|GATE/EIT]] trata do apoio com projetos de eletrônica e instrumentação (em fase de criação).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
A seguir podem ser encontradas informações importantes sobre procedimentos internos:&lt;br /&gt;
&lt;br /&gt;
[[Informações Internas]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos&amp;diff=169</id>
		<title>Equipamentos</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos&amp;diff=169"/>
		<updated>2024-10-02T11:54:02Z</updated>

		<summary type="html">&lt;p&gt;Mseren: link dos Equipamentos de Laboratório de Ensino&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Equipamentos&lt;br /&gt;
&lt;br /&gt;
Texto geral.&lt;br /&gt;
&lt;br /&gt;
Divididos em:&lt;br /&gt;
&lt;br /&gt;
* [[Equipamentos do LAMULT]] &lt;br /&gt;
* [[Equipamentos de Departamentos]]&lt;br /&gt;
* [[Equipamentos Laboratórios de Ensino]]&lt;br /&gt;
[[Template de Equipamento|Página template de equipamentos.]]&lt;br /&gt;
[[Categoria:Equipamentos]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos_Laborat%C3%B3rios_de_Ensino&amp;diff=168</id>
		<title>Equipamentos Laboratórios de Ensino</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos_Laborat%C3%B3rios_de_Ensino&amp;diff=168"/>
		<updated>2024-10-02T11:53:30Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Criou página com &amp;#039;* Laboratório de Eletrônica (LF-44)  * Laboratório de Ensino de Física Médica (LF-46) * Laboratório de Física Moderna (LF-47)  * Laboratório de Óptica (LF-42)  * Laboratório de Ensino de Raios X (LF-41)  * Laboratório de Vácuo e Criogenia (LF-43)&amp;#039;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;* Laboratório de Eletrônica (LF-44) &lt;br /&gt;
* Laboratório de Ensino de Física Médica (LF-46)&lt;br /&gt;
* Laboratório de Física Moderna (LF-47) &lt;br /&gt;
* Laboratório de Óptica (LF-42) &lt;br /&gt;
* Laboratório de Ensino de Raios X (LF-41) &lt;br /&gt;
* Laboratório de Vácuo e Criogenia (LF-43)&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos&amp;diff=167</id>
		<title>Equipamentos</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Equipamentos&amp;diff=167"/>
		<updated>2024-10-02T11:51:35Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Inclusão da categoria - Equipamentos de Laboratório&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Equipamentos&lt;br /&gt;
&lt;br /&gt;
Texto geral.&lt;br /&gt;
&lt;br /&gt;
Divididos em:&lt;br /&gt;
&lt;br /&gt;
* [[Equipamentos do LAMULT]] &lt;br /&gt;
* [[Equipamentos de Departamentos]]&lt;br /&gt;
* Equipamentos Laboratórios de Ensino &lt;br /&gt;
[[Template de Equipamento|Página template de equipamentos.]]&lt;br /&gt;
[[Categoria:Equipamentos]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=131</id>
		<title>APA</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=131"/>
		<updated>2024-07-31T11:39:54Z</updated>

		<summary type="html">&lt;p&gt;Mseren: INSERÇÃO DO EIT COM LINK&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Arquivo:3-2048x1152.png|alt=APA|miniaturadaimagem|APA]]&lt;br /&gt;
O GATE/APA oferece apoio de operação e manutenção a instrumentação científica utilizada em pesquisa e ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
Contato: gateapa@unicamp.br &lt;br /&gt;
&lt;br /&gt;
Saiba mais sobre os serviços que o GATE/APA oferece:&lt;br /&gt;
* [[Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)]]&lt;br /&gt;
* [[EIT|Eletrônica e Instrumentação (EIT)]]&lt;br /&gt;
* [[AAV|Apoio Audio Visual (AAV)]]&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;br /&gt;
[[Categoria:APA]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=49</id>
		<title>APA</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=49"/>
		<updated>2024-07-25T19:36:53Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
O GATE/APA oferece apoio de operação e manutenção a instrumentação científica utilizada em pesquisa e ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
Contato: gateapa@unicamp.br&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Saiba mais sobre os serviços que o GATE/APA oferece: &lt;br /&gt;
&lt;br /&gt;
* [[EIT|Eletrônica e Instrumentação (EIT)]]&lt;br /&gt;
* [[Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)]]&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=48</id>
		<title>APA</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=48"/>
		<updated>2024-07-25T19:35:45Z</updated>

		<summary type="html">&lt;p&gt;Mseren: link&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
O GATE/APA oferece apoio de operação e manutenção a instrumentação científica utilizada em pesquisa e ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
Contato: gateapa@unicamp.br&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Saiba mais sobre os serviços que o GATE/APA oferece: &lt;br /&gt;
&lt;br /&gt;
* [[Eit|Eletrônica e Instrumentação (EIT)]]&lt;br /&gt;
* [[Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)]]&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Laborat%C3%B3rios_de_Apoio_ao_Ensino_e_Pesquisa_(LAEP)&amp;diff=47</id>
		<title>Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Laborat%C3%B3rios_de_Apoio_ao_Ensino_e_Pesquisa_(LAEP)&amp;diff=47"/>
		<updated>2024-07-25T19:35:11Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Informações básica LAEP&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Os Laboratórios de Apoio ao Ensino e Pesquisa (LAEP) dividem-se em dois conjuntos de salas: Laboratórios de Ensino Básico (LEB) e Laboratórios de Ensino Profissional (LEP). &lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Laboratórios de Ensino Básico (LEB)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Os Laboratórios de Ensino Básico (LEB) são formados por cinco laboratórios para o ensino de física básica, em mecânica newtoniana, eletrostática, eletrodinâmica, análise de circuitos elétricos em DC e AC, e informática. Possui também 4 salas de estudos para metodologia de aprendizagem ativa e uma sala Maker, equipada com impressora 3D de volume útil de 64 litros de impressão.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Reservas de Salas do LEB:&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
A reserva de uso dos laboratórios do LEB é feita pela secretaria de graduação. Para consultar a disponibilidade das salas do LEB, consulte o sistema de reservas de salas do IFGW: https://reserva.ifi.unicamp.br/&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Uso da impressora 3D:&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
Se você tem interesse em utilizar a impressora 3D do LEB, clique o link a seguir para maiores informações:  https://portal.ifi.unicamp.br/servicos/equipamentos-de-acesso-controlado-eacs/impressora-3d&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Laboratórios de Ensino Profissional (LEP)&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
Os Laboratórios de Ensino Profissional (LEB) são formados por seis laboratórios para o ensino de física avançada: Laboratório de Raios X (LF-41), Laboratório de Ótica (LF-42), Laboratório de Criogenia e Vácuo (LF-43), Laboratório de Eletrônica (LF-44), Laboratório de Física Médica (LF-46) e Laboratório de Física Moderna). &lt;br /&gt;
&lt;br /&gt;
&#039;&#039;Reservas de Salas do LEP:&#039;&#039; &lt;br /&gt;
&lt;br /&gt;
A reserva de uso dos laboratórios do LEP é feita pela secretaria de graduação. Para consultar a disponibilidade das salas do LEP, consulte o sistema de reservas de salas do IFGW: https://reserva.ifi.unicamp.br/&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;&#039;&#039;Laboratórios que compõe o LEP:&#039;&#039;&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Raios X (LF-41)&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Óptica (LF-42)&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Criogenia e Vácuo (LF-43)&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Eletrônica (LF-44)&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Física Médica (LF-46)&#039;&#039;&#039; &lt;br /&gt;
* &#039;&#039;&#039;Laboratório de Ensino de Física Moderna (LF-47)&#039;&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Laborat%C3%B3rios_de_Apoio_ao_Ensino_e_Pesquisa_(LAEP)&amp;diff=46</id>
		<title>Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Laborat%C3%B3rios_de_Apoio_ao_Ensino_e_Pesquisa_(LAEP)&amp;diff=46"/>
		<updated>2024-07-25T19:30:38Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Criou página com &amp;#039;Os Laboratórios de Apoio ao Ensino e Pesquisa (LAEP) dividem-se em dois conjuntos de salas: Laboratórios de Ensino Básico (LEB) e Laboratórios de Ensino Profissional (LEP).      Laboratórios de Ensino Básico (LEB)  Os Laboratórios de Ensino Básico (LEB) são formados por cinco laboratórios para o ensino de física básica, em mecânica newtoniana, eletrostática, eletrodinâmica, análise de circuitos elétricos em DC e AC, e informática. Possui também 4 salas...&amp;#039;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Os Laboratórios de Apoio ao Ensino e Pesquisa (LAEP) dividem-se em dois conjuntos de salas: Laboratórios de Ensino Básico (LEB) e Laboratórios de Ensino Profissional (LEP). &lt;br /&gt;
&lt;br /&gt;
 &lt;br /&gt;
&lt;br /&gt;
Laboratórios de Ensino Básico (LEB)&lt;br /&gt;
&lt;br /&gt;
Os Laboratórios de Ensino Básico (LEB) são formados por cinco laboratórios para o ensino de física básica, em mecânica newtoniana, eletrostática, eletrodinâmica, análise de circuitos elétricos em DC e AC, e informática. Possui também 4 salas de estudos para metodologia de aprendizagem ativa e uma sala Maker, equipada com impressora 3D de volume útil de 64 litros de impressão.&lt;br /&gt;
&lt;br /&gt;
Reservas de Salas do LEB: &lt;br /&gt;
&lt;br /&gt;
A reserva de uso dos laboratórios do LEB é feita pela secretaria de graduação.&lt;br /&gt;
&lt;br /&gt;
Para consultar a disponibilidade das salas do LEB, consulte o sistema de reservas de salas do IFGW (Aqui) &lt;br /&gt;
 Para solicitar um agendamento abra um chamado na Fila “Graduação-Reserva-Salas” (Aqui) &lt;br /&gt;
Uso da impressora 3D: &lt;br /&gt;
&lt;br /&gt;
Se você tem interesse em utilizar a impressora 3D do LEB, clique o link a seguir para maiores informações:  https://portal.ifi.unicamp.br/servicos/equipamentos-de-acesso-controlado-eacs/impressora-3d&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=45</id>
		<title>APA</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=45"/>
		<updated>2024-07-25T19:28:54Z</updated>

		<summary type="html">&lt;p&gt;Mseren: link&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
O GATE/APA oferece apoio de operação e manutenção a instrumentação científica utilizada em pesquisa e ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
Contato: gateapa@unicamp.br&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Saiba mais sobre os serviços que o GATE/APA oferece: &lt;br /&gt;
&lt;br /&gt;
* [[Eit|Eletrônica e Instrumentação (EIT)]]&lt;br /&gt;
* Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=EIT&amp;diff=44</id>
		<title>EIT</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=EIT&amp;diff=44"/>
		<updated>2024-07-25T19:27:57Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Informações complementares&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
A área do Projetos de Eletrônica de Instrumentação (EIT) do GATE/APA foi criada para dar apoio ao desenvolvimento de equipamentos com circuitos elétricos, eletrônicos, mecânicos e de telecomunicações. Podemos auxiliar desde a concepção dos desenhos até a confecção de placas simples ou multicamadas. &lt;br /&gt;
&lt;br /&gt;
Os projetos são iniciados mediante a abertura de ordens de serviços pelos pesquisadores na Fila “GATE-Projetos“. A partir deste ponto, sua viabilidade é avaliada, dando sequência à concepção do desenho, testes com simulações mecânicas e eletrônicas para pré-aprovação e acompanhamento da confecção. Também, está dentro do escopo da área de Projetos:&lt;br /&gt;
&lt;br /&gt;
* Analisar solicitações de usuários, quanto à viabilidade, prazo de execução e custos;&lt;br /&gt;
* Listar os componentes e materiais necessários para a construção dos protótipos;&lt;br /&gt;
* Realizar ensaios preliminares de equipamentos quanto à conformidade a normas de  segurança elétrica.&lt;br /&gt;
* Follow-up dosprotótipos executados pelo GATE/APA/Projetos (possíveis revisões, consertos e propostas de melhoria);&lt;br /&gt;
* Prestar assessoria aos alunos e estagiários quanto à segurança e o funcionamento dos equipamentos de teste;&lt;br /&gt;
* Documentar os projetos executados;&lt;br /&gt;
&lt;br /&gt;
[[Arquivo:EIT-2048x1152.jpg|miniaturadaimagem|Sala S-307 no segundo piso do LEB, onde localiza-se o GATE/APA/EIT]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:EIT-2048x1152.jpg&amp;diff=43</id>
		<title>Arquivo:EIT-2048x1152.jpg</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=Arquivo:EIT-2048x1152.jpg&amp;diff=43"/>
		<updated>2024-07-25T19:25:49Z</updated>

		<summary type="html">&lt;p&gt;Mseren: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Sala LEB S-307&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=42</id>
		<title>APA</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=APA&amp;diff=42"/>
		<updated>2024-07-25T19:24:21Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Informações Básicas GATE/APA&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;br /&gt;
O GATE/APA oferece apoio de operação e manutenção a instrumentação científica utilizada em pesquisa e ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
Contato: gateapa@unicamp.br&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Saiba mais sobre os serviços que o GATE/APA oferece: &lt;br /&gt;
&lt;br /&gt;
* Eletrônica e Instrumentação (EIT) &lt;br /&gt;
* Laboratórios de Apoio ao Ensino e Pesquisa (LAEP)&lt;br /&gt;
&lt;br /&gt;
[[Categoria:GATE]]&lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
	<entry>
		<id>https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=41</id>
		<title>GATE</title>
		<link rel="alternate" type="text/html" href="https://gatewiki.ifi.unicamp.br/wiki/index.php?title=GATE&amp;diff=41"/>
		<updated>2024-07-25T19:22:11Z</updated>

		<summary type="html">&lt;p&gt;Mseren: Informações básicas do GATE&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;O Grupo de Apoio Técnico Especializado (GATE) foi instituído em março de 2019 no Instituto de Física Gleb Wataghin (IFGW).&lt;br /&gt;
&lt;br /&gt;
O objetivo do GATE é fornecer suporte abrangente para o ensino, pesquisa e extensão, contando com uma equipe altamente qualificada e multidisciplinar.&lt;br /&gt;
&lt;br /&gt;
Atualmente, o GATE está estruturado em três setores: Apoio Acadêmico (APA), Apoio Técnico e Suporte (ATS) e Operação de Equipamentos Multiusuários (OEM).&lt;br /&gt;
&lt;br /&gt;
O setor [[APA|GATE/APA]] é responsável por oferecer apoio técnico para a operação e manutenção dos equipamentos científicos utilizados em pesquisas e no ensino de graduação e pós-graduação do IFGW.&lt;br /&gt;
&lt;br /&gt;
O setor [[ATS|GATE/ATS]] presta serviços de suporte técnico aos laboratórios de pesquisa, incluindo elaboração de desenhos técnicos, confecção de peças, fornecimento de fluidos criogênicos, manutenção de bombas de vácuo, soldas especiais e confecção e reparo de utensílios de quartzo.&lt;br /&gt;
&lt;br /&gt;
O setor [[OEM|GATE/OEM]], por sua vez, é responsável pela operação e gestão do parque de equipamentos multiusuários do IFGW, que inclui LAMULT, Equipamentos do Acervo Controlado (EAC) e Equipamentos Multiusuários (EMU).  &lt;/div&gt;</summary>
		<author><name>Mseren</name></author>
	</entry>
</feed>